Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 111

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Validation study of thermal-hydraulics analysis code SPIRAL to a large-scale wire-wrapped fuel assembly sodium test at a low Reynolds number flow regime

Yoshikawa, Ryuji; Imai, Yasutomo*; Kikuchi, Norihiro; Tanaka, Masaaki; Gerschenfeld, A.*

Proceedings of 30th International Conference on Nuclear Engineering (ICONE30) (Internet), 10 Pages, 2023/05

Removal of core decay heat by utilizing natural circulation is expected as a significant measure to enhance the safety of sodium-cooled fast reactors (SFRs). Accurate evaluation of the temperature distribution in the fuel assembly (FA) at the low Re regime in natural circulation operation is demanded. A detailed thermal-hydraulics analysis code named SPIRAL has been developed to clarify thermal-hydraulic phenomena in the FA at various operation conditions. In this study, SPIRAL with the hybrid turbulence model was applied to analyze a large-scale fuel assembly experiment of a 91-pin bundle for two cases at the mixed and the natural convection conditions respectively in low Re regime with heat transfer from outside of the FA. The applicability of the SPIRAL to the thermal-hydraulics evaluation of FA at mixed and natural convection conditions was confirmed by the comparisons of temperatures predicted by SPIRAL with those measured in the experiment.

Journal Articles

Comparison on safety features among HTGR's Reactor Cavity Cooling Systems (RCCSs)

Takamatsu, Kuniyoshi; Funatani, Shumpei*

Proceedings of 2023 International Congress on Advanced in Nuclear Power Plants (ICAPP 2023) (Internet), 17 Pages, 2023/04

The objectives of this study are as follows: to understand the characteristics, degree of passive safety features for heat removal were compared for RCCSs based on atmospheric radiation and based on atmospheric natural circulation under the same conditions. Therefore, the authors concluded that the proposed RCCS based on atmospheric radiation has the advantage that the temperature of the RPV can be stably maintained against disturbances in the outside air (ambient air). Moreover, methodology to utilize all the heat emitted from the RPV surface for increasing the degree of waste-heat utilization was discussed.

Journal Articles

Comparisons between passive RCCSs on degree of passive safety features against accidental conditions and methodology to determine structural thickness of scaled-down heat removal test facilities

Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*

Annals of Nuclear Energy, 162, p.108512_1 - 108512_10, 2021/11

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

The objectives of this study are as follows: to understand the characteristics, degree of passive safety features for heat removal were compared for RCCSs based on atmospheric radiation and based on atmospheric natural circulation under the same conditions. Next, simulations on accidental conditions, such as increasing average heat-transfer coefficient via natural convection due to natural disasters, were performed with STAR-CCM+, and methodology to control the amount of heat removal was discussed. As a result, a new RCCS based on atmospheric radiation is recommended because of the excellent degree of passive safety features/conditions, and the amount of heat removal by heat transfer surfaces which can be controlled. Finally, methodology to determine structural thickness of scaled-down heat removal test facilities for reproducing natural convection and radiation was developed, and experimental methods by using pressurized and decompressed chambers was also proposed.

Journal Articles

Comparison between passive reactor cavity cooling systems based on atmospheric radiation and atmospheric natural circulation

Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*

Annals of Nuclear Energy, 151, p.107867_1 - 107867_11, 2021/02

 Times Cited Count:1 Percentile:16.35(Nuclear Science & Technology)

A new RCCS with passive safety features consists of two continuous closed regions. One is a region surrounding RPV. The other is a cooling region with heat transferred to the ambient air. The new RCCS needs no electrical or mechanical driving devices. We compared the RCCS using atmospheric radiation with that using atmospheric natural circulation in terms of passive safety features and control methods for heat removal. The magnitude relationship for passive safety features is heat conduction $$>$$ radiation $$>$$ natural convection. Therefore, the magnitude for passive safety features of the former RCCS can be higher than that of the latter RCCS. In controlling the heat removal, the former RCCS changes the heat transfer area only. On the other hand, the latter RCCS needs to change the chimney effect. It is necessary to change the air resistance in the duct. Therefore, the former RCCS can control the heat removal more easily than the latter RCCS.

Journal Articles

Unsteady natural convection in a cylindrical containment vessel (CIGMA) with external wall cooling; Numerical CFD simulation

Hamdani, A.; Abe, Satoshi; Ishigaki, Masahiro; Shibamoto, Yasuteru; Yonomoto, Taisuke

Energies (Internet), 13(14), p.3652_1 - 3652_22, 2020/07

 Times Cited Count:6 Percentile:18.77(Energy & Fuels)

Journal Articles

Comparative methodology between actual RCCS and downscaled heat-removal test facility

Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*

Annals of Nuclear Energy, 133, p.830 - 836, 2019/11

 Times Cited Count:2 Percentile:21.58(Nuclear Science & Technology)

A RCCS having passive safety features through radiation and natural convection was proposed. The RCCS design consists of two continuous closed regions: an ex-reactor pressure vessel region and a cooling region with a heat-transfer surface to ambient air. The RCCS uses a novel shape to remove efficiently the heat released from the RPV through as much radiation as possible. Employing air as the working fluid and ambient air as the ultimate heat sink, the RCCS design can strongly reduce the possibility of losing the working fluid and the heat sink for decay-heat-removal. Moreover, the authors started experiment research with using a scaled-down heat-removal test facility. Therefore, this study propose a comparative methodology between an actual RCCS and a scaled-down heat-removal test facility.

Journal Articles

Fuel debris' air cooling analysis using a lattice Boltzmann method

Onodera, Naoyuki; Idomura, Yasuhiro; Kawamura, Takuma; Uesawa, Shinichiro; Yamashita, Susumu; Yoshida, Hiroyuki

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 6 Pages, 2019/05

A dry method is one of practical methods for decommissioning the TEPCO's Fukushima Daiichi Nuclear Power Station. Japan Atomic Energy Agency (JAEA) has been evaluating the air cooling performance by using the JUPITER code. However, the JUPITER code requires a large computational cost to capture debris' structures. To accelerate such CFD analyses, we use the CityLBM code, which is based on the lattice Boltzmann method (LBM) and is highly optimized for GPUs. The CityLBM code is validated against free convective heat transfer experiments at JAEA, and the similar accuracy as the JUPITER code is confirmed regarding the prediction capability of heat transfer and the resulting temperature distributions. It is also shown that the elapse time of a CityLBM simulation on GPUs is reduced to 1/6 compared with that of the corresponding JUPITER simulation on CPUs with the same number of GPUs and CPUs. The results show that the LBM is promising for accelerating thermal convective simulations.

Journal Articles

Establishment of numerical model to investigate heat transfer and flow characteristics by using scale model of vessel cooling system for HTTR

Takada, Shoji; Ngarayana, I. W.*; Nakatsuru, Yukihiro*; Terada, Atsuhiko; Murakami, Kenta*; Sawa, Kazuhiko*

Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 13 Pages, 2019/05

In the loss of core cooling test using HTTR, a technical issue is to improve prediction accuracy of temperature distribution of components in vessel cooling system (VCS). An establishment of reasonable 2D model was started by using numerical code FLUENT, which was validated using the test data by 1/6 scale model of VCS for HTTR. The pressure vessel (PV) temperature was set around 200$$^{circ}$$C attributed to relatively high ratio of natural convection heat transfer around 20% in total heat removal, which is useful for code to experiment benchmark to improve prediction accuracy. It is necessary to confirm heat transfer flow characteristics around the top of PV which is heated up by natural convection flow which was considered to be affected by separation, re-adhesion and transition flow. The k-$$omega$$-SST model was selected for turbulent calculation attributed to predict the effects mentioned above adequately. The numerical results using the k-$$omega$$-SST model reproduced the temperature distribution of PV especially the top region which is considered to be affected by separation, re-adhesion and transition flow in contract to that using k-$$varepsilon$$ model which does not account the effects.

Journal Articles

Improvement of heat-removal capability using heat conduction on a novel reactor cavity cooling system (RCCS) design with passive safety features through radiation and natural convection

Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*

Annals of Nuclear Energy, 122, p.201 - 206, 2018/12

 Times Cited Count:3 Percentile:30.05(Nuclear Science & Technology)

A RCCS having passive safety features through radiation and natural convection was proposed. The RCCS design consists of two continuous closed regions: an ex-reactor pressure vessel region and a cooling region with a heat-transfer surface to ambient air. The RCCS uses a novel shape to remove efficiently the heat released from the RPV through as much radiation as possible. Employing air as the working fluid and ambient air as the ultimate heat sink, the RCCS design can strongly reduce the possibility of losing the working fluid and the heat sink for decay-heat-removal. This study addresses an improvement of heat-removal capability using heat conduction on the RCCS. As a result, a heat flux removed by the RCCS could be doubled; therefore, it is possible to halve the height of the RCCS or increase the thermal reactor power.

Journal Articles

Experimental study on heat removal performance of a new Reactor Cavity Cooling System (RCCS)

Hosomi, Seisuke*; Akashi, Tomoyasu*; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*; Takamatsu, Kuniyoshi

Proceedings of 11th Korea-Japan Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS-11) (Internet), 7 Pages, 2018/11

A new RCCS with passive safety features consists of two continuous closed regions. One is a region surrounding RPV. The other is a cooling region with heat transferred to the ambient air. The new RCCS needs no electrical or mechanical driving devices. We started experiment research with using a scaled-down test section. Three experimental cases under different emissivity conditions were performed. We used Monte Carlo method to evaluate the contribution of radiation to the total heat released from the heater. As a result, after the heater wall was painted black, the contribution of radiation to the total heat could be increased to about 60%. A high emissivity of RPV surface is very effective to remove more heat from the reactor. A high emissivity of the cooling part wall is also effective because it not only increases the radiation emitted to the ambient air, but also may increase the temperature difference among the walls and enhance the convection heat transfer in the RCCS.

Journal Articles

Development of numerical simulation method to evaluate heat transfer performance of air around fuel debris, 2; Validation of JUPITER for free convection heat transfer

Uesawa, Shinichiro; Yamashita, Susumu; Shibata, Mitsuhiko; Yoshida, Hiroyuki

Proceedings of 25th International Conference on Nuclear Engineering (ICONE-25) (CD-ROM), 7 Pages, 2017/07

Journal Articles

Study of the flow characteristics of coolant channel of fuel blocks for HTGR

Tsuji, Nobumasa*; Ohashi, Kazutaka*; Tazawa, Yujiro*; Tachibana, Yukio; Ohashi, Hirofumi; Takamatsu, Kuniyoshi

FAPIG, (190), p.20 - 24, 2015/07

In a loss of forced cooling accident, decay heat in HTGRs must be removed by radiation, thermal conduction and natural convection. Passive heat removal performance is of primary concern for enhancing inherent safety features of HTGRs. Therefore, the thermal hydraulic analyses for normal operation and a loss of forced cooling accident are conducted by using thermal hydraulic CFD code. And further, a multi-hole type fuel block of MHTGR is also modeled and the flow and heat transfer characteristics are compared with a pin-in-block type fuel block.

Journal Articles

Infrared thermography for analyzing heat transfer and fluid flow of benard-cell convection in a rectangular container with free surface

Inagaki, Terumi*; Hatori, Masakazu*; Suzuki, Tomohiro*; Shiina, Yasuaki

Proceedings of International Conference on Advanced Optical Diagnostics in Fluids, Solids and Combustion (VSJ-SPIE '04) (CD-ROM), 9 Pages, 2004/12

no abstracts in English

Journal Articles

Heat transfer phenomenon of natural convection in an open vessel and its infrared sensing

Inagaki, Terumi*; Kaneko, Toshinobu*; Hatori, Masakazu*; Shiina, Yasuaki

Nihon Kikai Gakkai Rombunshu, B, 70(699), p.279 - 286, 2004/11

no abstracts in English

Journal Articles

Research and development on passive cooling system

Takada, Shoji

Nuclear Engineering and Design, 233(1-3), p.185 - 195, 2004/10

 Times Cited Count:6 Percentile:40.72(Nuclear Science & Technology)

Experiments are carried out to investigate the effects of the natural convection of superheated gas as well as of the stand pipes on the temperature distributions of the components and the heat removal performance in the water-cooling panel system for the MHTGR for decay heat removal, and to verify the design and evaluation methods. The numerical results of the code THANPACST2 are compared with the experimental data to verify the numerical methods and axi-symmetric model proposed, which can simulate the three-dimensional configuration of the stand pipes on the upper head of the pressure vessel by using porous body cells. The experiments revealed that temperatures increased with elevation on the upper head, because the stand pipes restrict radiation heat transfer to the upper cooling panel and reduce the heat transfer area on the upper head which was superheated by natural convection of helium gas in the pressure vessel. The numerical methods were able to closely duplicate the pattern of the rising temperature profile with elevation around the top of the upper head.

Journal Articles

An Experimental study of heat transfer in an open thermosyphon

Imai, Etsuya*; Shiina, Yasuaki; Hishida, Makoto*

Heat Transfer-Asian Research, 30(4), p.301 - 312, 2001/06

no abstracts in English

Journal Articles

Three-dimensional numerical simulations of dust mobilization and air ingress characteristics in a fusion reactor during a LOVA event

Takase, Kazuyuki

Fusion Engineering and Design, 54(3-4), p.605 - 615, 2001/04

 Times Cited Count:12 Percentile:64.73(Nuclear Science & Technology)

no abstracts in English

JAEA Reports

CompalisonoFnlermohydraulicCharacteristicsintheuseofvariousCoolants

; ; *; Yamaguchi, Akira

JNC TN9400 2000-109, 96 Pages, 2000/11

JNC-TN9400-2000-109.pdf:9.56MB

Numerical calculations were carried out for a free surface sloshing, a thermal stratification, a thermal striping, and a natural convection as key phenomena of in-vessel thermohydraulics in future fast reactor systems with various fluids as coolants. This numerical work was initiaied based on a recognition that the fundamental characteristics of the phenomena have been unsolved quantitatively in the use of various coolants. From the analysis for the phenomena, the following results were obtained. [Free Surface Sloshing phenomena] (1)Ther is no remarkable difference betweeen liquid sodium and luquid Pb-Bi in characteristics of internal flows and free surface charatristics based on Fr number. (2)the AQUA-VOF code has a potentiall enough to evaluate gas entrainment behavior from the free surface including the internal flow characteristics. [thermal Stratification Phenomena] (1)On-set position of thermal entainment process due to dynamic vortex flows was moved to downstream direction with decreasing of Ri number. 0n the other hand, the position in the case of C0$$_{2}$$ gas was shifted to upstream side with decreasing of Ri number. (2)Destruction speed of the thermal stratyification interface was dependent on thermal diffusivity as fluid properties. therefor it was concluded that an elimination method is necessary for the interface generated in C0$$_{2}$$ gas. [thermal Striping Phenomena] (1)Large amplitudes of fluid temperature fluctuations was reached to down stream area in the use of CO$$_{2}$$ gas, due to larger fluid viscosity and smaller thermal diffusivity, compared with liquid sodium and liquid Pb-Bi cases. (2)To simulate thermal striping conditions such as amplitude and frequency of the fluid temperature fluctuations, it isnecessary for coincidences of Re number for the amplitude and of velocity value for the frequency, in various coolants. [Natural Convection Phenomena] (1)Fundamental behavior of the natural convection in various coolant follows buoyant jet ....

JAEA Reports

Study on natural convection heat transfer in a vertical enclosure of double coaxial cylinder; Cooling by natural circulation of air

Zhang, Y.*; Takeda, Tetsuaki; Inaba, Yoshitomo

JAERI-Tech 2000-065, 109 Pages, 2000/11

JAERI-Tech-2000-065.pdf:6.17MB

no abstracts in English

Journal Articles

Deposition of cesium iodide particles in bends and sections of vertical pipe under severe accident conditions

Hidaka, Akihide; Shibazaki, Hiroaki*; Yoshino, T.*; Sugimoto, Jun

Journal of Aerosol Science, 31(9), p.1045 - 1059, 2000/09

 Times Cited Count:1 Percentile:18.22(Engineering, Chemical)

no abstracts in English

111 (Records 1-20 displayed on this page)